Quantcast
Channel: Active questions tagged mount+fstab - Ask Ubuntu
Viewing all articles
Browse latest Browse all 699

How to deal with errors=remount-ro?

$
0
0

Yesterday this message appeared on my screen while booting OS after powerfailure "due to low battery backup"

You are in emergency mode, After logging in type "journalctl -xb" to view system logs, "systemctl reboot" to reboot, "systemctl default" or"exit" to boot into default mode. Press enter for maintenance (or press control-D to contnue):

Following helped me getting rid of emergency mode

fsck -y /dev/sda*

*First I used sda7 but boot was successful for only one time and again entered into emergency mode, then i used sda5 and sda7 one by one.

It worked for me but by applying command nano /etc/fstab or vi /etc/fstab, output is annoying as it says

/ file was on /dev/sda5 during installation ext4 errors=remount-ro 0 1

How to deal with errors=remount-ro ? I don't know if it might harm my system.

OS = UBUNTU 18.04


Smartmontools result:

=== START OF READ SMART DATA SECTION ===SMART overall-health self-assessment test result: PASSEDGeneral SMART Values:Offline data collection status:  (0x80) Offline data collection activity                    was never started.                    Auto Offline Data Collection: Enabled.Self-test execution status:      ( 121) The previous self-test completed having                    the read element of the test failed.Total time to complete Offline data collection:        (  120) seconds.Offline data collectioncapabilities:            (0x51) SMART execute Offline immediate.                    No Auto Offline data collection support.                    Suspend Offline collection upon new                    command.                    No Offline surface scan supported.                    Self-test supported.                    No Conveyance Self-test supported.                    Selective Self-test supported.SMART capabilities:            (0x0003) Saves SMART data before entering                    power-saving mode.                    Supports SMART auto save timer.Error logging capability:        (0x01) Error logging supported.                    General Purpose Logging supported.Short self-test routine recommended polling time:    (   2) minutes.Extended self-test routinerecommended polling time:    ( 105) minutes.SCT capabilities:          (0x003d) SCT Status supported.                    SCT Error Recovery Control supported.                    SCT Feature Control supported.                    SCT Data Table supported.SMART Attributes Data Structure revision number: 16Vendor Specific SMART Attributes with Thresholds:ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE  1 Raw_Read_Error_Rate     0x002f   100   100   050    Pre-fail  Always       -       0  2 Throughput_Performance  0x0027   100   100   050    Pre-fail  Always       -       0  3 Spin_Up_Time            0x0023   100   100   002    Pre-fail  Always       -       1368  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       5899  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       8  7 Seek_Error_Rate         0x002f   100   100   050    Pre-fail  Always       -       0  8 Seek_Time_Performance   0x0025   100   100   050    Pre-fail  Offline      -       0  9 Power_On_Hours          0x0032   061   061   000    Old_age   Always       -       15756 10 Spin_Retry_Count        0x0033   217   100   030    Pre-fail  Always       -       0 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       5587183 Runtime_Bad_Block       0x0032   100   100   001    Old_age   Always       -       0184 End-to-End_Error        0x0033   100   100   097    Pre-fail  Always       -       0185 Unknown_Attribute       0x0032   100   100   001    Old_age   Always       -       65535187 Reported_Uncorrect      0x0032   001   001   000    Old_age   Always       -       24102188 Command_Timeout         0x0032   100   099   000    Old_age   Always       -       8189 High_Fly_Writes         0x003a   100   100   001    Old_age   Always       -       0190 Airflow_Temperature_Cel 0x0022   063   045   040    Old_age   Always       -       37 (Min/Max 30/39)191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       563192 Power-Off_Retract_Count 0x0022   100   100   000    Old_age   Always       -       23069024193 Load_Cycle_Count        0x0032   070   070   000    Old_age   Always       -       308244194 Temperature_Celsius     0x0022   063   045   040    Old_age   Always       -       37 (Min/Max 30/39)196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       1197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       -       3320199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0SMART Error Log Version: 1ATA Error Count: 25061 (device log contains only the most recent five errors)    CR = Command Register [HEX]    FR = Features Register [HEX]    SC = Sector Count Register [HEX]    SN = Sector Number Register [HEX]    CL = Cylinder Low Register [HEX]    CH = Cylinder High Register [HEX]    DH = Device/Head Register [HEX]    DC = Device Command Register [HEX]    ER = Error register [HEX]    ST = Status register [HEX]Powered_Up_Time is measured from power on, and printed asDDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,SS=sec, and sss=millisec. It "wraps" after 49.710 days.Error 25061 occurred at disk power-on lifetime: 15747 hours (656 days + 3 hours)  When the command that caused the error occurred, the device was active or idle.  After command completion occurred, registers were:  ER ST SC SN CL CH DH  -- -- -- -- -- -- --  40 41 50 ae 2c 01 40  Error: UNC at LBA = 0x00012cae = 76974  Commands leading to the command that caused the error were:  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name  -- -- -- -- -- -- -- --  ----------------  --------------------  60 80 58 00 2d 01 40 00      01:24:48.589  READ FPDMA QUEUED  60 80 50 80 2c 01 40 00      01:24:48.558  READ FPDMA QUEUED  60 80 48 00 2c 01 40 00      01:24:48.558  READ FPDMA QUEUED  60 80 40 80 2b 01 40 00      01:24:48.558  READ FPDMA QUEUED  60 80 38 00 2b 01 40 00      01:24:48.557  READ FPDMA QUEUEDError 25060 occurred at disk power-on lifetime: 15745 hours (656 days + 1 hours)  When the command that caused the error occurred, the device was active or idle.  After command completion occurred, registers were:  ER ST SC SN CL CH DH  -- -- -- -- -- -- --  40 41 f0 ae 2c 01 40  Error: UNC at LBA = 0x00012cae = 76974  Commands leading to the command that caused the error were:  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name  -- -- -- -- -- -- -- --  ----------------  --------------------  60 80 f8 60 9f 50 40 00      00:00:20.324  READ FPDMA QUEUED  60 01 f0 ae 2c 01 40 00      00:00:20.277  READ FPDMA QUEUED  60 80 e8 e0 9e 50 40 00      00:00:20.277  READ FPDMA QUEUED  60 80 e0 60 9e 50 40 00      00:00:20.277  READ FPDMA QUEUED  2f 00 01 10 00 00 28 00      00:00:20.276  READ LOG EXTError 25059 occurred at disk power-on lifetime: 15745 hours (656 days + 1 hours)  When the command that caused the error occurred, the device was active or idle.  After command completion occurred, registers were:  ER ST SC SN CL CH DH  -- -- -- -- -- -- --  40 41 d8 ae 2c 01 40  Error: UNC at LBA = 0x00012cae = 76974  Commands leading to the command that caused the error were:  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name  -- -- -- -- -- -- -- --  ----------------  --------------------  60 01 d8 ae 2c 01 40 00      00:00:20.185  READ FPDMA QUEUED  60 02 d0 32 2c 01 40 00      00:00:20.185  READ FPDMA QUEUED  60 02 c8 30 2c 01 40 00      00:00:20.185  READ FPDMA QUEUED  61 08 c0 38 75 03 40 00      00:00:20.184  WRITE FPDMA QUEUED  60 3d b8 71 2c 01 40 00      00:00:20.169  READ FPDMA QUEUEDError 25058 occurred at disk power-on lifetime: 15744 hours (656 days + 0 hours)  When the command that caused the error occurred, the device was active or idle.  After command completion occurred, registers were:  ER ST SC SN CL CH DH  -- -- -- -- -- -- --  40 41 18 ae 2c 01 40  Error: UNC at LBA = 0x00012cae = 76974  Commands leading to the command that caused the error were:  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name  -- -- -- -- -- -- -- --  ----------------  --------------------  60 01 18 ae 2c 01 40 00      00:00:20.376  READ FPDMA QUEUED  60 80 10 c0 bf 2e 40 00      00:00:20.376  READ FPDMA QUEUED  60 80 08 40 bf 2e 40 00      00:00:20.376  READ FPDMA QUEUED  2f 00 01 10 00 00 28 00      00:00:20.370  READ LOG EXT  60 80 08 40 bf 2e 40 00      00:00:20.329  READ FPDMA QUEUEDError 25057 occurred at disk power-on lifetime: 15744 hours (656 days + 0 hours)  When the command that caused the error occurred, the device was active or idle.  After command completion occurred, registers were:  ER ST SC SN CL CH DH  -- -- -- -- -- -- --  40 41 00 ae 2c 01 40  Error: UNC at LBA = 0x00012cae = 76974  Commands leading to the command that caused the error were:  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name  -- -- -- -- -- -- -- --  ----------------  --------------------  60 01 00 ae 2c 01 40 00      00:00:20.291  READ FPDMA QUEUED  60 02 f8 32 2c 01 40 00      00:00:20.291  READ FPDMA QUEUED  60 02 f0 30 2c 01 40 00      00:00:20.291  READ FPDMA QUEUED  61 08 e8 38 75 03 40 00      00:00:20.290  WRITE FPDMA QUEUED  60 3d e0 71 2c 01 40 00      00:00:20.275  READ FPDMA QUEUEDSMART Self-test log structure revision number 1Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error# 1  Extended offline    Completed: read failure       90%     15753         76974# 2  Extended offline    Aborted by host               40%        31         -# 3  Short offline       Completed without error       00%        30         -# 4  Extended offline    Completed without error       00%        30         -# 5  Short offline       Completed without error       00%        28         -SMART Selective self-test log data structure revision number 1 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS    1        0        0  Not_testing    2        0        0  Not_testing    3        0        0  Not_testing    4        0        0  Not_testing    5        0        0  Not_testingSelective self-test flags (0x0):  After scanning selected spans, do NOT read-scan remainder of disk.If Selective self-test is pending on power-up, resume after 0 minute delay.

Viewing all articles
Browse latest Browse all 699

Trending Articles